Home>Products>Water Purification Solutions>IP-77-12 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid
DuPont Ultrafiltration IP-77-12 MODELS
Need a CAD or 3D Model?
IP-77-12 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid
category
Water Purification Solutions
DuPont Ultrafiltration IP-77-12 SPECIFICATIONS
IP-77-12 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Low Fouling Type with easy-to-use 41.4 Flow m3/day parts WATER PURIFICATION MANUFACTURER graphics, giving 11000 Flow gpd you the ability to check parts availability, Water Purification Solutions pricing, examine remanufactured options.
- DuPont Ultrafiltration
IP-77-12
- Low Fouling
- 11000
- 41.4
- LFC2
- 101.6
- 40
- 41.37
- 600
- WATER PURIFICATION MANUFACTURER2020-07-10 09:46:19
Welcome to my shop! Glad to serve you! Please send your question!
IP-77-12 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Characteristics
- 45.0
- 113
- 33.9
- 365
- 95.0 %
DuPont Ultrafiltration IP-77-12 IP-77-12 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Product identifiers
Water Purification Solutions Trade Shows | |||||||||
---|---|---|---|---|---|---|---|---|---|
No. | Brand | Type | Flow gpm | pH range | Length mm | Weight kg | Weight lb | Application | Flow m3/day |
IP-77-12 IntegraPac Ultrafiltration Skid | DuPont Ultrafiltration | Industrial | 264 | 2-11 | 2330 | 939 | 2070 | Ultra pure water, Beverage, Boiler water | 1440 |
BW30HP-404 Filmtec Membranes Reverse Osmosis Element for pre-Treatment | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
Hypershell NF245-390-FF DuPont Ultrafiltration Nanofiltration Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
RO-3840/30-FF DuPont Ultrafiltration RO and Desalination Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
TMG20D-4 Toray Membranes Brackish Water Reverse Osmosis Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
HSRO-390-FF Filmtec Membranes Heat Sanitizable RO Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
LE-4 DuPont Ultrafiltration Low Energy RO Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
SW30HRLE-4 Filmtec Membranes Seawater High Rejection Reverse Osmosis Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
TM820S-44 Toray Membranes Sea Water Reverse Osmosis Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
SW30-4021 DuPont Ultrafiltration Seawater Reverse Osmosis Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
SG30LE-4 Filmtec Membranes Semiconductor Grade RO Element | Type:Low Fouling; Brand:Hydranautics Membranes; Flow gpd:11000; Flow m3/day:41.4; Part Number:LFC2; Length in cm:101.6; Length in inch:40; Max Pressure kPa:41.37; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:33.9; Membrane Active Area ft2:365; Minimum NaCl rejection percentage:95.0 %; |
IP-77-12 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Video
IntegraPac™ IP-77 Module - DuPont
IntegraPac IP-77 Modules are made from high-strength, PVDF hollow fiber membranes engineered to reduce design and fabrication requirements. The fibers have a ...
IntegraPac™ Ultrafiltration Modules Model Product Data Sheet
These modules are an ideal choice for systems requiring a small footprint. The IP-77 and IPD-77 modules offer a high effective.3 pages
IntegraPac™ Ultrafiltration Skid With IP-77XP or IPD ... - DuPont
Description. The IntegraPac™ skid from DuPont Water. Solutions is a pre-engineered, standardized skid design consisting of IntegraPac™ ultrafiltration.4 pages
DuPont Ultrafiltration IP-77-12 IntegraPac Ultrafiltration Skid
Ultrafiltration (UF) is a pressure-driven purification process that separates particulate matter from soluble compounds using an ultrafine membrane media.
IntegraPac™ IPD-77XP Module - DuPont
IntegraPac™ IPD-77XP Ultrafiltration Modules are used in IntegraPac IPD-77XP Ultrafiltration Skids. With its direct module coupling resulting in a compact ...
MEMBRANE ULTRAFILTRAZIONE ULTRAFILTRATION ...
This section includes the description of DuPont Ultrafiltration ... IP/D- 77XP modules and skids and IntegraFlux™ UXA-2680XP modules. ... 12Nm3/h/module.
IntegraPac™ Ultrafiltration Modules Product Data Sheet
Model IP-51XP, IPD-51XP, IP-77XP and IPD-77XP. Description. IntegraPac™ Ultrafiltration (UF) modules with XP fiber are made ... 12 Nm3/hr. 7.1 scfm.4 pages
IntegraPac™ IP-77 Skid - DuPont
IntegraPac™ IP-77 Ultrafiltration Skids are a pre-engineered, standardized skid design consisting of six to twenty-two IntegraPac™ IP-77 Ultrafiltration ...
Contact Us
- WATER PURIFICATION MANUFACTURER
DuPont Ultrafiltration IP-77-12 Technical Articles
What are the 5 steps of water filtration? |
What are the methods of treatment of water? |
What are the two primary reasons for water treatment? |
Water Purification Solutions CATEGORIES
Customers Who Viewed DuPont Ultrafiltration IP-77-12 Also Viewed
- SW30HRLE-4 Filmtec Membranes Seawater High Rejection Reverse Osmosis Element
- BW30HP-404 Filmtec Membranes Reverse Osmosis Element for pre-Treatment
- HSRO-390-FF Filmtec Membranes Heat Sanitizable RO Element
- SW30-4021 DuPont Ultrafiltration Seawater Reverse Osmosis Element
- SG30LE-4 Filmtec Membranes Semiconductor Grade RO Element